Kyakkyawan Mahimmancin Sinanci Mai Sashe na 3 Hematology Na'urar Buɗe Tsarin Na'urar Na'urar Kiwon Lafiyar Kiwon Lafiyar Jama'a An Ƙirƙira don Ƙananan Asibiti

Ka'idoji

● Hanyar rashin ƙarfi

● Hanyar launi na Cyanide kyauta


Cikakken Bayani

Tags samfurin

Ƙirƙirar ƙima, kyawu da dogaro sune ainihin ƙimar ƙungiyarmu.Wadannan ka'idoji a yau fiye da kowane lokaci sun zama tushen nasararmu a matsayin babban kamfani na tsakiya mai aiki na kasa da kasa don Kyakkyawan ingancin China 3-Part Hematology Auto Open System Analyzer wanda aka ƙera don Ƙananan Clinic, Tunaninmu yawanci shine don taimakawa gabatar da amincewar kowane masu siye tare da bayar da mafi kyawun samar da mu, da kuma samfurin da ya dace.
Ƙirƙirar ƙima, kyawu da dogaro sune ainihin ƙimar ƙungiyarmu.Waɗannan ƙa'idodin a yau fiye da kowane lokaci sun zama tushen nasararmu a matsayin babban kamfani mai girman aiki na duniya donGabobin wucin gadi na kasar Sin, Jimlar Tsarin Maye gurbin gwiwa, Tare da ruhun "bashi na farko, ci gaba ta hanyar kirkire-kirkire, haɗin gwiwa na gaske da haɓaka haɗin gwiwa", kamfaninmu yana ƙoƙari ya haifar da kyakkyawar makoma tare da ku, ta yadda ya zama dandamali mafi mahimmanci don fitar da kayayyakin mu a kasar Sin!
0244

Ƙayyadaddun Fasaha

Ma'auni

21 da za a iya ba da rahoto:

WBC, Lym#, Mid#, Gran#, Lym%, Mid%, Gran%, RBC,

HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV,

PDW, PCT, P-LCR, P-LCC

3 Histograms (WBC, RBC, PLT)

Yanayin Gwaji

Jini gaba ɗaya mai jiwuwa, jini gabaɗayan capillary da Prediluted

Kayan aiki

Gwaje-gwaje 60/awa

Ayyuka

Siga Tsawon Layi Ci gaba CV
WBC 0-300×109 /L ≤0.5% ≤2.0%
RBC 0-8×1012 /L ≤0.5% ≤1.5%
HGB 0-250g/L ≤0.5% ≤1.5%
PLT 0-3000×109 /L ≤1.0% ≤4.0%

Samfurin Girma

≤10 ul

Ƙwaƙwalwar Data

Har zuwa sakamako 100,000 (ciki har da histograms da bayanin haƙuri)

Nunawa

10.4 inch tabawa

Kwafi

Gina firinta na thermal ko firinta na waje

Interface

● 4 USB, 1 LAN, 1 RS-232

● Taimakawa haɗin LIS

● Katin RF don tsarin rufewar reagent (na zaɓi)

Girma/Nauyi

L * W * H = 411*315*416(mm)

Nauyi: 21kg

Muhallin Aiki

● Ƙarfin wutar lantarki: ac100-240V, 50/60Hz

● Zazzabi: 10-30 ℃

● Lashi: 20-85%

● Matsin iska: 70-106KPa

● Latitude Aiki: ≤3500mInnovation, mafi kyau da kuma dogara su ne ainihin dabi'un ƙungiyarmu.Wadannan ka'idoji a yau fiye da kowane lokaci sun zama tushen nasararmu a matsayin babban kamfani na tsakiya mai aiki na kasa da kasa don Kyakkyawan ingancin China 3-Part Hematology Auto Open System Analyzer wanda aka ƙera don Ƙananan Clinic, Tunaninmu yawanci shine don taimakawa gabatar da amincewar kowane masu siye tare da bayar da mafi kyawun samar da mu, da kuma samfurin da ya dace.
Kyakkyawan inganciGabobin wucin gadi na kasar Sin, Jimlar Tsarin Maye gurbin gwiwa, Tare da ruhun "bashi na farko, ci gaba ta hanyar kirkire-kirkire, haɗin gwiwa na gaske da haɓaka haɗin gwiwa", kamfaninmu yana ƙoƙari ya haifar da kyakkyawar makoma tare da ku, ta yadda ya zama dandamali mafi mahimmanci don fitar da kayayyakin mu a kasar Sin!